cherry-pick(#34430): docs: switch gracefulShutdown to primarily mention SIGTERM and add Docker comment (#34431)
1 parent 2b8d1ce commit 2811a1d

File tree

3 files changed

+6
-5
lines changed

3 files changed

+6
-5
lines changed

docs/src/test-api/class-testconfig.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -629,7 +629,7 @@ export default defineConfig({
629629
- `stdout` ?<["pipe"|"ignore"]> If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`.
630630
- `stderr` ?<["pipe"|"ignore"]> Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`.
631631
- `timeout` ?<[int]> How long to wait for the process to start up and be available in milliseconds. Defaults to 60000.
632-
- `gracefulShutdown` ?<[Object]> How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored.
632+
- `gracefulShutdown` ?<[Object]> How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting down a Docker container requires `SIGTERM`.
633633
- `signal` <["SIGINT"|"SIGTERM"]>
634634
- `timeout` <[int]>
635635
- `url` ?<[string]> The url on your http server that is expected to return a 2xx, 3xx, 400, 401, 402, or 403 status code when the server is ready to accept connections. Redirects (3xx status codes) are being followed and the new location is checked. Either `port` or `url` should be specified.

docs/src/test-webserver-js.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -37,7 +37,7 @@ export default defineConfig({
3737
| `stdout` | If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`. |
3838
| `stderr` | Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`. |
3939
| `timeout` | How long to wait for the process to start up and be available in milliseconds. Defaults to 60000. |
40-
| `gracefulShutdown` | How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored. |
40+
| `gracefulShutdown` | How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting down a Docker container requires `SIGTERM`. |
4141

4242
## Adding a server timeout
4343

packages/playwright/types/test.d.ts

Lines changed: 4 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -9645,9 +9645,10 @@ interface TestConfigWebServer {
96459645

96469646
/**
96479647
* How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal:
9648-
* 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit
9649-
* within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't
9650-
* support `SIGINT` and `SIGTERM` signals, so this option is ignored.
9648+
* 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit
9649+
* within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent.
9650+
* Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting
9651+
* down a Docker container requires `SIGTERM`.
96519652
*/
96529653
gracefulShutdown?: {
96539654
signal: "SIGINT"|"SIGTERM";

0 commit comments