You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The old 1-bit hamming layout requires ECC data to be placed at a
fixed offset, and not necessarily at the end of the OOB area.
Add this old layout back in order to fix legacy setups.
Fixes: 41b207a ("mtd: nand: implement the default mtd_ooblayout_ops")
Cc: <[email protected]>
Signed-off-by: Alexander Couzens <[email protected]>
Acked-by: Boris Brezillon <[email protected]>
Signed-off-by: Brian Norris <[email protected]>