s390/cpum_sf: Add data entry sizes to sampling trailer entry
The CPU Measurement sampling facility creates a trailer entry for each
Sample-Data-Block of stored samples. The trailer entry contains the sizes
(in bytes) of the stored sampling types:
- basic-sampling data entry size
- diagnostic-sampling data entry size
Both sizes are 2 bytes long.
This patch changes the trailer entry definition to reflect this.
Fixes: fcc77f5 ("s390/cpum_sf: Atomically reset trailer entry fields of sample-data-blocks")
Signed-off-by: Thomas Richter <[email protected]>
Reviewed-by: Hendrik Brueckner <[email protected]>
Signed-off-by: Martin Schwidefsky <[email protected]>