According to SBSA spec v3.1 section 5.3:
All registers are 32 bits in size and should be accessed using
32-bit reads and writes. If an access size other than 32 bits
is used then the results are IMPLEMENTATION DEFINED.
[...]
The Generic Watchdog is little-endian
The current code uses readq to read the watchdog compare register
which does a 64-bit access. This fails on ThunderX2 which does not
implement 64-bit access to this register.
Fix this by using lo_hi_readq() that does two 32-bit reads.
Signed-off-by: Jayachandran C <[email protected]>
Reviewed-by: Guenter Roeck <[email protected]>
Signed-off-by: Guenter Roeck <[email protected]>
Signed-off-by: Wim Van Sebroeck <[email protected]>
0 commit comments