i2c/pca954x: Initialize the mux to disconnected state
pca954x power-on default is channel 0 connected. If multiple pca954x
muxes are connected to the same physical I2C bus, the parent bus will
see channel 0 devices behind both muxes by default. This is bad.
Scenario:
-- pca954x @ 0x70 -- ch 0 (I2C-bus-101) -- EEPROM @ 0x50
|
I2C-bus-1 ---
|
-- pca954x @ 0x71 -- ch 0 (I2C-bus-111) -- EEPROM @ 0x50
1. Load I2C bus driver: creates I2C-bus-1
2. Load pca954x driver: creates virtual I2C-bus-101 and I2C-bus-111
3. Load eeprom driver
4. Try to read EEPROM @ 0x50 on I2C-bus-101. The transaction will also bleed
onto I2C-bus-111 because pca954x @ 0x71 channel 0 is connected by default.
Fix: Initialize pca954x to disconnected state in pca954x_probe()
Signed-off-by: Petri Gynther <[email protected]>
Signed-off-by: Jean Delvare <[email protected]>