Description

With this commit on this code line, Cordio reset sequence won't get done.
The handling case for HCI_OPCODE_LE_WRITE_DEF_DATA_LEN should send HciReadLocalVerInfoCmd().

Pull request type

[x] Fix
[ ] Refactor
[ ] Target update
[ ] Functionality change
[ ] Docs update
[ ] Test update
[ ] Breaking change

Reviewers

Release Notes

@ciarmcom ciarmcom requested review from a team March 14, 2019 10:00
@ciarmcom
Copy link
Member

@desmond-blue, thank you for your changes.
@ARMmbed/mbed-os-pan @ARMmbed/mbed-os-maintainers please review.

Copy link
Member

@paul-szczepanek-arm paul-szczepanek-arm left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Yeah, run into same with new cordio (paul-szczepanek-arm@b96c0ac). I think this old one works because extended reset isn't run.

@0xc0170
Copy link
Contributor

0xc0170 commented Mar 15, 2019

No more changes are expected there.

This was added to the rollup PR #10116 and it's currently in CI. If any new commit comes, please let us know immediately.

@0xc0170 0xc0170 merged commit a70f0e6 into ARMmbed:master Mar 15, 2019
@0xc0170 0xc0170 removed the needs: CI label Mar 15, 2019